LAMPING OPTIONS
SPECIFICATIONS
CATALOG NUMBER
SPECIFICATIONS
22
46 5th Street, Berk
eley
, CA 94
710
• T
el: 510.845.27
60
• Fax: 510
.845.277
6
• Email:
[email protected] • PeerlessLighting.com__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
Type: ________________________
Project: ______________________
1
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Prima” are registered trademarks of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx
Indirect-Direct T5/T5HO
PRM4 Prima I/D
Examples: PRM4 1 54T5HO SPR OPD WPB 40FT R12 120 GEB10 2SE EL SCT LP841 F1/24 C110 — PRM4 2 54T5HO WHR OPD SSB 12FT R8 277 GEB10 DCT LP830 F2/15 C518 GLR
Suspended PRM4
Prima I/D
Indirect-Direct T5/T5HO
PRM4 - 1 PRM4 - 2 PRM4 - 3
9”
3”
9”
3”
9”
3”
Construction
9” x 3” one-piece cold-rolled steel housing with flat
end plate.
Reflectors
Die-formed highly reflective white or specular
reflector.
Shielding
Semi-specular parabolic aluminum baes.
Finish
Fine-textured, white paint or silver paint to match
anodized aluminium are standard. Custom colors
available, consult factory.
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG
fixture wires. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors
included. UL and C-UL listed.
Luminaire Length
4’
1
⁄4”, 8’ and 12’ lengths in a single section for
exact suspension spacing of 4’, 8’ and 12’. For total
luminaire length add
1
⁄16” for each end cap. Using
internal joiners, 4’, 8’ and 12’ sections can be joined
to form longer-length luminaires.
__________ __________ __________ __________ __________ __________ _________ __________ __________ __________
Luminaire
PRM4
# of
Lamps in
Cross
Section
1
2
3
28T5
28W T5
54T5HO 54W T5HO
Reflector
WHR White
Reflector
(Standard)
SPR
Specular
Reflector
Shielding
OPD Bae
w/std
brightness
opal
diuser
overlay
Bae
SSB Semi-
specular
bae
WPB
White
painted
bae
Luminaire
Row
Length
X FT
(4’ increments)
Maximum
Section
Length
R4 4’ section(s)
R8 8’ section(s)
R12 12’ section(s)
Voltage
120
277
347
Ballast Type
GEB10 <10% THD Electronic
ADEZ
1,2
Advance Mark 10 dim
DMHL3D
1
Lutron Hi-Lume dim
OSDIM
1,2
Osram 0-10V dim
Reference Ballast Wizard on website
or consult factory for other options.
______________ ________________ __________ ________________ ______________ ______________ ______________ _________________________________
# of Emergency
Modules
(Blank) None
1SE 1 section
2SE 2 sections
XSE X sections
Emergency Type
3
(Blank) None
EC Emergency
circuit
EL
1
Emergency
battery pack
EN
1
Emergency
battery pack
w/night light
circuit
Switching
SCT Single
circuit
DCT
Dual
circuit
Lamp Color
L/LP No lamp
LP830 3000k 80+ CRI
LP835 3500k 80+ CRI
LP841 4100k 80+ CRI
Available with T5 only:
LP830P
3000K 80+
CRI Premier
LP835P
3500K 80+
CRI Premier
LP841P
4100K 80+
CRI Premier
Reference Lamp Chart on
website or consult factory
for other options.
Mounting Type /
F1/ T-bar ceiling (universal
mounting bracket)
F1A/
T-bar ceiling (UMB with
integrated J-box)
F2/
Hard ceiling (horizontal
J-box)
F3/
Rigid stem
Overall
Suspension
12 12”
15 15”
18 18”
21 21”
24 24”
XX XX”
Overall
suspension is
measured from
ceiling to bottom
of luminaire.
Finish
C110 Painted
aluminum
(low gloss)
C518
White (fine-
textured low
gloss)
C099
Custom
finish
Options
ACG Adjustable cable grippers
BLK Black cord, cord manager and canopy (not
available with F3)
CP
Chicago plenum (available with F1A only)
DL Damp location label
DU Dust cover
ELH Emergency through wiring w/separate feed
ELS Emergency through wiring w/single feed,
shared neutral
ELS2
Emergency through wiring w/single feed,
separate neutrals
GLR
Fusing (fast blow)
GMF Fusing (slow blow)
MCS Matching feed canopy at support
NEPP5D nLight enabled control module per row/zone
NYC New York City code
OJB Oset junction box
SLP Sloped ceiling (for 10-45°, must be specified
with F2, ACG and OJB options)
XXXX
Integrated sensor; choose options and obtain
code on page 2
Notes:
1 Not available in 347V
2 Not available with 28T5 lamps
3 EL and EC are installed in last 4’ of luminaire sections.
Separate feed required unless ELS or ELS2 is specified
Comentários a estes Manuais