WEIGHTS & SUPPORT SPACING
MOUNTING DETAIL
PHOTOMETRICS
22
46 5th Street, Berk
eley
, CA 94
710
• T
el: 510.845.27
60
• Fax: 510
.845.277
6
• Email:
[email protected] • PeerlessLighting.comJOINING CONFIGURATIONS
SCALE 1 / 40
SPW9 2T8 OPD DU
CROSS SECTIONSCALE 1 / 2
DU
(Option)
OPD
(Option)
7
8
"
1
3
4
"
9
3
8
"
2
3
8
"
WIREWAY CHANNEL
ENDCAPS
1
1
2
" MTG HOLES TO
BOTTOM OF HOUSING
SWITCH BOX AT FEED- BY OTHERS
(HORIZONTALLY MOUNTED)
10"
3
4
"
11
16
"
2
7
16
"
MOUNTING
HOLES
(2) #10-24X3/8"
MTG. SCREW
FEED COVER
(2) 1/4" DIA. MTG BOLTS
- BY OTHERS
EXTRUDED ALUMINUM
MOUNTING PLATE
STANDARD SECTIONS
1
1
⁄
8
” end cap
4’-0” O.A.
8’-0” O.A.
12’-0” O.A.
Key:
Support location
Standard feed location
•
EM feed location
PLAN VIEW
2’-8”
6’-8”
5’-4”5’-4”
500
1000
1000
Type: ________________________
Project: ______________________
1-LAMP T5HO
87.7% eciency
4385 delivered lumens
65.5% up / 34.5% down
2-LAMP T5HO
91.8% eciency
9183 delivered lumens
63.8% up / 36.2% down
Actual performance may dier as a result of end-user environment and application.
2
© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx
Indirect-Direct T5/T5HO
SPW4 Staple Wall Bae I/D
Staple Wall Bae I/D
Indirect-Direct T5/T5HO
Wall Mount SPW4